Home | About us | Editorial Board | Search | Ahead of print | Current Issue | Archives | Instructions | Online submissionContact Us   |  Subscribe   |  Advertise   |  Login  Page layout
Wide layoutNarrow layoutFull screen layout
Lung India Official publication of Indian Chest Society  
  Users Online: 1225   Home Print this page  Email this page Small font size Default font size Increase font size


 
  Table of Contents    
CASE REPORT
Year : 2017  |  Volume : 34  |  Issue : 1  |  Page : 61-64  

Role of radial endobronchial ultrasound-guided transbronchial needle aspiration in the diagnosis of pulmonary nodules: Case report and literature review


1 Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research, Chandigarh, India
2 Department of Cytology, Postgraduate Institute of Medical Education and Research, Chandigarh, India

Date of Web Publication30-Dec-2016

Correspondence Address:
Ritesh Agarwal
Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research, Sector-12, Chandigarh - 160 012
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-2113.197094

Rights and Permissions
   Abstract 

The diagnosis of pulmonary nodules can be made using several methods including computed tomography (CT)-guided fine-needle aspiration (FNA), radial endobronchial ultrasound (EBUS)-guided sampling techniques (transbronchial lung biopsy [TBLB], transbronchial brush, bronchoalveolar lavage, or transbronchial needle aspiration [TBNA]), or occasionally with convex probe (CP) EBUS-TBNA. While CT-guided FNA is associated with a high (25%) rate of pneumothorax, the CP-EBUS cannot reach lesions beyond the interlobar region. Radial EBUS-guided TBLB and transbronchial brushing are excellent modalities in the evaluation of peripheral pulmonary lesions. However, these techniques cannot access lesions that are located adjacent to the proximal segmental bronchus, due to the presence of a cartilaginous wall. Herein, we describe a 58-year-old man, who presented with a lung nodule in the right middle lobe, wherein radial EBUS-guided TBNA proved to be the most appropriate diagnostic modality. We also discuss the current utility of radial EBUS-guided TBNA in day-to-day practice.

Keywords: Endobronchial ultrasound, guide sheath, lung cancer, transbronchial needle aspiration


How to cite this article:
Dhooria S, Sehgal IS, Gupta N, Aggarwal AN, Behera D, Agarwal R. Role of radial endobronchial ultrasound-guided transbronchial needle aspiration in the diagnosis of pulmonary nodules: Case report and literature review. Lung India 2017;34:61-4

How to cite this URL:
Dhooria S, Sehgal IS, Gupta N, Aggarwal AN, Behera D, Agarwal R. Role of radial endobronchial ultrasound-guided transbronchial needle aspiration in the diagnosis of pulmonary nodules: Case report and literature review. Lung India [serial online] 2017 [cited 2019 Jul 21];34:61-4. Available from: http://www.lungindia.com/text.asp?2017/34/1/61/197094


   Introduction Top


The sampling of lung nodules or masses located close to the hilum is a peculiar problem. Before 1992, conventional transbronchial needle aspiration (TBNA) was the only bronchoscopic method available for accessing lesions in the lung parenchyma that were too central for a transbronchial lung biopsy (TBLB).[1],[2],[3] Moreover, only those lesions that were adjacent to the airways or that could be identified during fluoroscopy were amenable for TBNA. The subsequent introduction of radial endobronchial ultrasound (EBUS) revolutionized the diagnosis of intraparenchymal pulmonary lesions.[4],[5],[6] Apart from guiding transbronchial brushings and biopsies, the radial probe EBUS was also used for performing TBNA from lesions located adjacent to the airways.[5],[7] However, the major drawback was that the procedure was not performed in real-time.

The introduction of convex probe EBUS (CP-EBUS) transformed the sampling of lesions located adjacent to the proximal airways as these could be accessed under real-time ultrasound guidance, thereby greatly increasing the diagnostic yield.[8],[9] In fact, the CP-EBUS has replaced radial EBUS-guided TBNA not only for mediastinal lesions but also for lung masses, in contact with major airways or esophagus.[10],[11] Currently, the radial EBUS is used primarily for accessing peripheral pulmonary lesions (PPLs), with the help of TBLB, bronchial brushing and bronchoalveolar lavage (BAL).[12] Although PPLs can also be accessed with the help of transthoracic ultrasound or computed tomography (CT)-guided fine needle aspiration (FNA), there is a significant risk of pneumothorax (about 25%).[13]

Herein, we describe a patient in whom radial EBUS-guided TBNA turned out to be the most suitable technique for accessing a lung lesion located adjacent to the proximal airway. We also review the current concepts of TBNA performed during the radial EBUS procedure.


   Case Report Top


A 58-year-old man presented with a complaint of headache of 2-month duration. There was no history of fever, vomiting, altered sensorium, or neurological deficit. The patient complained of breathlessness on exertion, but there were no symptoms of cough, chest pain, or hemoptysis. The patient was a smoker with a smoking history of 20 pack years. Auscultation of the chest revealed decreased breath sounds over the right upper lobe area. Laboratory investigations revealed anemia (hemoglobin, 9.2 g/dL) and hypoalbuminemia (albumin, 3.1 g/dL). Magnetic resonance imaging of the brain showed the presence of multiple space occupying lesions. CT of the thorax showed a large bulla in the right upper lobe and emphysema in both the lung fields. A spiculated nodule measuring 2.8 cm × 2.7 cm was seen in the right middle lobe, about 1.5 cm away from the hilum [Figure 1]a and [Figure 1]b.
Figure 1: Computed tomography chest showing a spiculated nodule in the middle lobe of the right lung (a, coronal section; b, axial section). The nodule is surrounded by lung parenchyma on all sides and is away from the hilum. Radial ultrasound image (c) showing the lung nodule along with the placement of the radial probe in the lateral segment of the right middle lobe (inset). (d) A cluster of tumor cells showing moderate nuclear pleomorphism, round nuclei, coarse chromatin, occasional prominent nucleoli and moderate amount of vacuolated cytoplasm with intracytoplasmic mucin (arrows, MGG, ×40)

Click here to view


Flexible bronchoscopy (BF-P180, Olympus, Japan; external diameter 4.9 mm, channel size 2.0 mm) was performed in the supine position under conscious sedation (midazolam and pentazocine) and topical anesthesia.[14] Airway inspection revealed no abnormalities. The flexible bronchoscope was removed, and CP-EBUS bronchoscope (BF-UC-180F, external diameter 6.9 mm, Olympus, Japan) was inserted for sampling the lesion. However, the CP-EBUS scope could not be negotiated into the middle lobe. Subsequently, the radial EBUS probe (UM-S20-17S radial ultrasound probe, Olympus Japan; 1.4 mm distal end diameter, 20 MHz operating frequency) placed in a guide sheath (K-201, outer diameter 1.95 mm, Olympus, Japan) was used for localizing the nodule.[15] The lesion was visualized adjacent to the lateral segment of the right middle lobe at the very proximal end of the segmental bronchus. The radial probe was removed, and TBNA was performed using a 21-G needle (Smooth Shot, NA-401D 1321; minimal channel size required 2 mm, Olympus, Japan) at the visually chosen site under endoscopic vision [Figure 1]c. The needle was moved to and fro 10–15 times within the mass. Three passes were obtained from the same site, and the aspirate was submitted for cytological examination.[16] Brush cytology and TBLB were considered inappropriate due to the proximal location of the nodule.

Cytological examination revealed clusters of tumor cells with intracytoplasmic mucin suggestive of adenocarcinoma [Figure 1]d. The patient was administered dexamethasone and phenytoin in view of the brain metastases. He was planned for palliative radiotherapy and single agent chemotherapy in view of his poor performance status (Karnofsky Performance Score 60). However, the patient developed recurrent seizures and succumbed to his illness.


   Discussion Top


The present case illustrates the utility of radial EBUS-guided TBNA in the era of CP EBUS-TBNA. The index patient had a solitary pulmonary nodule located about 2 cm from the hilum. The nodule was localized at the proximal part of the lateral segment of the right middle lobe. We were unable to negotiate the CP-EBUS to the segmental bronchus of the middle lobe as the diameter of the EBUS scope is 6.9 mm. In the near future, an EBUS scope with a smaller diameter (5.9 mm) may allow real-time access of intrapulmonary lesions surrounding the segmental bronchi.[17] CT-guided FNA would have entailed a high risk of pneumothorax in view of the extensive emphysema.[13] Therefore, a radial EBUS-guided sampling was judged to be the safest and the most appropriate method.

Among the sampling techniques performed with a radial EBUS probe, TBLB and brushing would have a very low likelihood of yielding a diagnosis in this patient as the biopsy forceps or the brush cannot pierce the cartilaginous proximal bronchi and reach the lesion lying underneath the wall. Moreover, the bronchial cartilage was not involved, as evident from the radial EBUS images, thus reducing the chance of finding malignant cells on bronchial brushings. A BAL would also be unlikely to yield a diagnosis in the presence of a discrete nodule. We could not perform a TBNA through the radial probe guide sheath, a method that has been recently described.[18] This is because, we used a smaller caliber guide sheath through which a 21-G TBNA needle (that requires a minimum channel size of 2 mm) could not be inserted. Thus, a conventional TBNA at the site of the lesion visually chosen with the help of the radial EBUS probe was considered the most appropriate procedure. Alternatively, a needle brush, which combines a bronchial brush with a needle could also have been employed to access the nodule.[19] As compared to TBNA without a brush, this technique would have provided an additional specimen for cytological examination.

Before the advent of the CP-EBUS, radial EBUS-guided TBNA was routinely used for localizing lesions adjacent to the airways (located both in the mediastinum and in the lung parenchyma), which were then sampled with the conventional TBNA needle.[5],[20] With the advent of the CP-EBUS probe, the radial EBUS is no longer utilized for accessing airway-adjacent lesions (including the mediastinum and the lung hilum, up to the interlobar region). In fact, the radial EBUS-guided TBNA is not commonly employed for lesions located within the lung parenchyma also, despite the presence of evidence for its efficacy.[21] In a recent report of 581 patients in the ACCP Quality Improvement Registry, Evaluation and Education registry that described the performance of bronchoscopy for PPLs, only 47 patients underwent a TBNA guided by radial EBUS.[22]

Two recent studies have described the performance of radial EBUS-guided TBNA using a guide sheath in certain specific circumstances.[6],[18] On several occasions while performing radial EBUS, the probe cannot reach the center of the lesion; the lesion is thus visualized eccentrically on one side of the probe, rather than concentrically around the probe. The yield of EBUS is significantly less when the probe does not reach the center of the lesion as compared to the situation when it does. Takai et al. have emphasized on the efficacy and safety of radial EBUS-guided TBNA technique for lesions where the radial probe is seen “outside” the lesion rather than “within.”[18] In another retrospective study, Hayama et al. have described the use of fluoroscopy-guided TBNA for lesions, which were not visualized by the radial EBUS probe.[6] Interestingly, the lesions that were not initially visible with radial EBUS became visible after performing the TBNA procedure. The authors attribute this to the phenomenon of the TBNA needle cutting open a passage through which the probe, when subsequently reinserted, can reach the lesion. Brushings and forceps biopsies can then be performed, thereby, increasing the diagnostic yield.[6]

What is the current place of TBNA in radial EBUS-guided sampling? In our opinion, radial EBUS-guided TBNA should be routinely performed in sampling PPLs as it has been shown to significantly increase the diagnostic yield when added to EBUS-guided conventional diagnostic procedures (TBLB, brushings, BAL).[21] In the absence of smaller diameter CP-EBUS, the radial EBUS-guided TBNA currently remains the best technique for accessing intrapulmonary lesions surrounding the segmental bronchi, as demonstrated in the index case. Finally, it is an important technique for especially enhancing the yield of radial EBUS for PPLs where the radial probe is seen “outside” the lesion rather than “within,”[18] or in situ ations where the PPL is not initially visualized on radial EBUS.[6]

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Agarwal R, Aggarwal AN, Gupta D. Efficacy and safety of conventional transbronchial needle aspiration in sarcoidosis: A systematic review and meta-analysis. Respir Care 2013;58:683-93.  Back to cited text no. 1
    
2.
Wang KP, Haponik EF, Britt EJ, Khouri N, Erozan Y. Transbronchial needle aspiration of peripheral pulmonary nodules. Chest 1984;86:819-23.  Back to cited text no. 2
    
3.
Gupta D, Gulati M, Rajwanshi A. Fluoroscopic transbronchial fine needle aspiration for diagnosis of peripheral pulmonary nodules. Indian J Chest Dis Allied Sci 1996;38:163-7.  Back to cited text no. 3
    
4.
Hürter T, Hanrath P. Endobronchial sonography: Feasibility and preliminary results. Thorax 1992;47:565-7.  Back to cited text no. 4
    
5.
Shannon JJ, Bude RO, Orens JB, Becker FS, Whyte RI, Rubin JM, et al. Endobronchial ultrasound-guided needle aspiration of mediastinal adenopathy. Am J Respir Crit Care Med 1996;153(4 Pt 1):1424-30.  Back to cited text no. 5
    
6.
Hayama M, Izumo T, Chavez C, Matsumoto Y, Tsuchida T, Sasada S. Additional transbronchial needle aspiration through a guide sheath (GS-TBNA) for peripheral pulmonary lesions that cannot be detected by radial EBUS. Clin Respir J 2016; [doi: 10.1111/crj.12413].  Back to cited text no. 6
    
7.
Herth F, Becker HD, Ernst A. Conventional vs endobronchial ultrasound-guided transbronchial needle aspiration: A randomized trial. Chest 2004;125:322-5.  Back to cited text no. 7
    
8.
Krasnik M, Vilmann P, Larsen SS, Jacobsen GK. Preliminary experience with a new method of endoscopic transbronchial real time ultrasound guided biopsy for diagnosis of mediastinal and hilar lesions. Thorax 2003;58:1083-6.  Back to cited text no. 8
    
9.
Gupta D, Dadhwal DS, Agarwal R, Gupta N, Bal A, Aggarwal AN. Endobronchial ultrasound-guided transbronchial needle aspiration vs conventional transbronchial needle aspiration in the diagnosis of sarcoidosis. Chest 2014;146:547-56.  Back to cited text no. 9
    
10.
Dhooria S, Aggarwal AN, Gupta D, Behera D, Agarwal R. Utility and safety of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration in mediastinal lymph node sampling: Systematic review and meta-analysis. Respir Care 2015;60:1040-50.  Back to cited text no. 10
    
11.
Dhooria S, Aggarwal AN, Singh N, Gupta D, Behera D, Gupta N, et al. Endoscopic ultrasound-guided fine-needle aspiration with an echobronchoscope in undiagnosed mediastinal lymphadenopathy:First experience from India. Lung India 2015;32:6-10.  Back to cited text no. 11
[PUBMED]  Medknow Journal  
12.
Hsia DW, Jensen KW, Curran-Everett D, Musani AI. Diagnosis of lung nodules with peripheral/radial endobronchial ultrasound-guided transbronchial biopsy. J Bronchology Interv Pulmonol 2012;19:5-11.  Back to cited text no. 12
    
13.
Wahidi MM, Govert JA, Goudar RK, Gould MK, McCrory DC; American College of Chest Physicians. Evidence for the treatment of patients with pulmonary nodules: When is it lung cancer?: ACCP evidence-based clinical practice guidelines (2nd edition). Chest 2007;132 3 Suppl: 94S-107S.  Back to cited text no. 13
    
14.
Kaur H, Dhooria S, Aggarwal AN, Gupta D, Behera D, Agarwal R. A randomized trial of 1% vs 2% lignocaine by the spray-as-you-go technique for topical anesthesia during flexible bronchoscopy. Chest 2015;148:739-45.  Back to cited text no. 14
    
15.
Sehgal IS, Dhooria S, Aggarwal AN, Behera D, Agarwal R. Use of radial probe endobronchial ultrasound for the diagnosis of peripheral pulmonary lesion:First report from India. Lung India 2016;33:212-5.  Back to cited text no. 15
[PUBMED]  Medknow Journal  
16.
Dhooria S, Agarwal R, Aggarwal AN, Bal A, Gupta N, Gupta D. Differentiating tuberculosis from sarcoidosis by sonographic characteristics of lymph nodes on endobronchial ultrasonography: A study of 165 patients. J Thorac Cardiovasc Surg 2014;148:662-7.  Back to cited text no. 16
    
17.
Wada H, Hirohashi K, Nakajima T, Anayama T, Kato T, Grindlay A, et al. Assessment of the new thin convex probe endobronchial ultrasound bronchoscope and the dedicated aspiration needle: A preliminary study in the porcine lung. J Bronchology Interv Pulmonol 2015;22:20-7.  Back to cited text no. 17
    
18.
Takai M, Izumo T, Chavez C, Tsuchida T, Sasada S. Transbronchial needle aspiration through a guide sheath with endobronchial ultrasonography (GS-TBNA) for peripheral pulmonary lesions. Ann Thorac Cardiovasc Surg 2014;20:19-25.  Back to cited text no. 18
    
19.
Wang KP, Britt EJ. Needle brush in the diagnosis of lung mass or nodule through flexible bronchoscopy. Chest 1991;100:1148-50.  Back to cited text no. 19
    
20.
Okamoto H, Watanabe K, Nagatomo A, Kunikane H, Aono H, Yamagata T, et al. Endobronchial ultrasonography for mediastinal and hilar lymph node metastases of lung cancer. Chest 2002;121:1498-506.  Back to cited text no. 20
    
21.
Chao TY, Chien MT, Lie CH, Chung YH, Wang JL, Lin MC. Endobronchial ultrasonography-guided transbronchial needle aspiration increases the diagnostic yield of peripheral pulmonary lesions: A randomized trial. Chest 2009;136:229-36.  Back to cited text no. 21
    
22.
Ost DE, Ernst A, Lei X, Kovitz KL, Benzaquen S, Diaz-Mendoza J, et al. Diagnostic yield and complications of bronchoscopy for peripheral lung lesions. Results of the AQuIRE registry. Am J Respir Crit Care Med 2016;193:68-77.  Back to cited text no. 22
    


    Figures

  [Figure 1]



 

Top
  
 
  Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Case Report
   Discussion
    References
    Article Figures

 Article Access Statistics
    Viewed1089    
    Printed6    
    Emailed0    
    PDF Downloaded253    
    Comments [Add]    

Recommend this journal