CASE REPORT
Year : 2017  |  Volume : 34  |  Issue : 2  |  Page : 182-184  

Thoracoscopic foreign body removal and repair of bronchus intermedius following injury during failed bronchoscopic retrieval


1 Centre for Chest Surgery, Sir Ganga Ram Hospital, New Delhi, India
2 Department of Anaesthesia and Pain Medicine, Sir Ganga Ram Hospital, New Delhi, India

Date of Web Publication1-Mar-2017

Correspondence Address:
Belal Bin Asaf
Room 2328, Super Speciality and Research Block, Sir Ganga Ram Hospital, Old Rajinder Nagar, New Delhi
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-2113.201296

Rights and Permissions
   Abstract 

Aspiration of foreign body (FB) into the airways is common in children and continues to be a cause for morbidity and mortality. We report herein, successful thoracoscopic management of a child who aspirated a large magnetic FB into his right bronchus and developed a tear of bronchus intermedius (BI) during an attempt at bronchoscopic retrieval using rigid bronchoscope. The impacted FB was successfully removed thoracoscopically followed by thoracoscopic BI repair.

Keywords: Aspirated foreign body, bronchus repair, foreign body, thoracoscopy, video assisted thoracic surger


How to cite this article:
Asaf BB, Vijay C L, Bishnoi S, Dua N, Kumar A. Thoracoscopic foreign body removal and repair of bronchus intermedius following injury during failed bronchoscopic retrieval. Lung India 2017;34:182-4

How to cite this URL:
Asaf BB, Vijay C L, Bishnoi S, Dua N, Kumar A. Thoracoscopic foreign body removal and repair of bronchus intermedius following injury during failed bronchoscopic retrieval. Lung India [serial online] 2017 [cited 2017 Apr 26];34:182-4. Available from: http://www.lungindia.com/text.asp?2017/34/2/182/201296


   Introduction Top


Aspiration of foreign body (FB) into the airways is common in children and continues to be a cause for morbidity and mortality. It requires a prompt diagnosis and early treatment to reduce the potentially fatal consequences. Most are retrieved successfully by rigid or fiberoptic bronchoscope, though the latter is more reliable. Occasionally, in difficult foreign bodies, not only is retrieval unsuccessful, but also there may be an injury to the airway with its attendant complications. Such situations then require an emergency thoracotomy to salvage the situation and repair the airway. We report herein, successful thoracoscopic management of a child who aspirated a large magnetic FB into his right bronchus and developed a tear of bronchus intermedius (BI) during an attempt at bronchoscopic retrieval using rigid bronchoscope. The impacted FB was successfully removed thoracoscopically followed by thoracoscopic BI repair. To the best of our knowledge, it is the first such report from an Indian centre.


   Case Report Top


A 7-year-old, previously healthy boy, developed a severe cough with respiratory distress following accidental aspiration of an FB (piece of magnet) with which he was playing. He was initially treated with nebulization and oxygen therapy. Chest X-ray revealed a metallic FB in the right hilar area [Figure 1]. He was referred to a higher center for bronchoscopic removal of the FB, where he reported the next day and underwent rigid bronchoscopy under general anesthesia for removal of the FB. A large, bullet-shaped metallic FB was visualized in the BI. Attempts to grab it by any kind of forceps only pushed it distally. Several attempts to engage it in a dormia basket were also unsuccessful. After nearly 2 h of attempts at removal, the child was noticed to have developed subcutaneous emphysema in the neck which started progressing rapidly suggesting the possibility of airway injury. A tear could be seen in the BI which was partially traversed by the FB. The bronchoscopic procedure was abandoned, ventilation through the endotracheal tube was continued, and a 16F chest tube was inserted into the right chest. There was no fall in oxygen saturation, and he was hemodynamically stable. With a diagnosis of suspected BI injury, he was transferred to our hospital for surgical management.
Figure 1: Preoperative chest X-ray showing the aspirated foreign body

Click here to view


At a presentation in our emergency department, the patient was on mechanical ventilation through an endotracheal tube with stable hemodynamic parameters. Subcutaneous emphysema was noted in the neck and upper chest. He had reduced air entry in the right lower zone. Consent for thoracoscopy/thoracotomy was taken from the parents, and the child was immediately taken up for thoracoscopy under general anesthesia. Single lung ventilation with collapse of the right lung was achieved by selective intubation of the left main bronchus under bronchoscopic guidance. The child was placed in left lateral position with 30° anterior tilt (semi-prone position). Three 5 mm ports were created: camera port in 7th intercostal space (ICS) posterior axillary line and two working ports with right one in 4th ICS slightly posterior to posterior axillary line and left one in 9th ICS in the vertical line from the tip of the scapula. A 5 mm high definition telescope was used for visualization through the camera port, and two atraumatic graspers were used for dissection.

On entering the right pleural cavity evidence of atelectatic collapse was seen in the right lower lobe with minimal fluid and formation of early fibrinous exudate over the lower lobe. The right upper lobe was not adequately collapsed because of being inflated by the leak from around the cuff of the endotracheal tube. At this point, the table was tilted anteriorly, and CO2 insufflation at the pressure of 4 mm of Hg was used to enable us to see the posterior hilum adequately. The mediastinal pleural over the posterior hilum and the BI was intact and was seen bulging with ventilation suggesting leak from the airway. The lung was retracted anteriorly, and the posterior mediastinal pleura was opened. The BI was visualized. A 1 cm × 0.5 cm rent was noted in the BI through which the blackish FB was seen [Figure 2]. Although it was seen easily, multiple attempts to hold and remove it with an atraumatic laparoscopic instrument through the defect were not successful on account of the conical part of the body being tightly impacted distally. The FB was finally removed by pushing over the distal BI with an atraumatic bowel grasper and using a Maryland forceps in the other hand to overturn the FB and delivering it out of the bronchus. It was confirmed to be a magnetic object because it stuck to metallic instrument [Figure 2]. It was placed in a glove finger and taken out through one of the ports [Figure 3]. An endotracheal suction catheter was passed through one of the ports and guided into distal BI. Mucopurulent secretions were sucked out. Thereafter, the defect in the BI was closed with interrupted stitches using 3-0 polydiaxanone suture by thoracoscopic intracorporeal suturing (three stitches). The cuff of the endotracheal tube in the left bronchus was now deflated to allow ventilation gases to escape to right bronchus to do underwater leak test on the repaired BI. There was no air leak. A 20 Fr chest tube was placed in the right chest cavity, instruments and the two working ports were removed. Moreover, the telescope was withdrawn to just allow a view of inside. The endotracheal tube was now withdrawn into the trachea under bronchoscopic guidance to check for inflation of the right lung. The right upper lobe expanded immediately whereas the middle and lower lobes expanded slowly. At the end, complete expansion of all the lobes was observed. The telescope was also removed, and all the ports were closed. The total operating time (incision to closure) was 45 min. The child withstood the procedure well, was extubated on the table and shifted to recovery room. The air entry was now good and equal on both the sides, there was no air leak in the chest tube, and postoperative chest X-ray showed good lung expansion. He was allowed orally 2 h later and discharged the next day on parent's request on oral antibiotics and pain killers with ICD in situ. He was reviewed in the outpatient department 2 days later, and the chest tube was removed. He is presently doing well.
Figure 2: Thoracoscopic view of the procedure. (a) Foreign body seen peeking through the tear in bronchus intermedius marked by lines. (b and c) Retrieval being attempted with thoracoscopic instruments. (d) Foreign body retrieved and seen stuck to metal tip of the instrument due to magnetic properties of the foreign body

Click here to view
Figure 3: Retrieved foreign body and the surgical scars on 3rd postoperative day

Click here to view



   Discussion Top


FB aspiration into the airway is common and continues to be a cause of morbidity and mortality in young children. History, clinical examination, and X-rays usually provide the diagnosis. The real challenge lies in retrieval of the FB without physical injury to airway and in a safe way. Rigid bronchoscopy is the most suitable procedure for its removal.[1] Bronchoscopy is a life-saving procedure for FB removal in an emergency where it serves both as a diagnostic as well as a therapeutic procedure.[2] Most of the procedures are carried out with the rigid ventilating bronchoscope and grasping forceps, under general anesthesia. This system has saved innumerable precious lives up till now.[3] However, several complications of rigid bronchoscopy such as trauma to the teeth, oropharynx, vocal cords or other glottic structures, laryngospasm, pneumothorax, hemorrhage, and even death have been reported.[4],[5] Attempt to remove stuck FB can cause injury to tracheobronchial tree which may then necessitate surgical intervention as in our case. Conventionally, such injuries have been managed by thoracotomy. However, in view of the less invasive nature of thoracoscopy together with lesser pain, shorter recovery, shorter chest tube duration time and better cosmetic outcomes, it should be preferred over open approach wherever such approach is feasible, and necessary expertise is available.


   Conclusion Top


Thoracoscopy is a safe and efficient approach for management of patients with aspirated FB in whom initial attempts at removal by rigid bronchoscopy has failed or has caused inadvertent injury to the airway. However, hemodynamic stability of the patient and availability of necessary expertise are mandatory requirements for such endeavors.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Cohen S, Pine H, Drake A. Use of rigid and flexible bronchoscopy among pediatric otolaryngologists. Arch Otolaryngol Head Neck Surg 2001;127:505-9.  Back to cited text no. 1
    
2.
Mahajan JK, Rathod KK, Bawa M, Rao KL. Tracheobronchial foreign body aspirations: Lessons learned from a 10-year audit. J Bronchology Interv Pulmonol 2011;18:223-8.  Back to cited text no. 2
    
3.
Arif N, Ashfaq AH, Ajmal M, Mahmood K. Rigid bronchoscopy for tracheobromchial foreign bodies in children at Holy Family Hospital, Rawalpindi. Gomal J Med Sci 2014;12:101-5.  Back to cited text no. 3
    
4.
Drummond M, Magalhaes A, Hespanhol V, Marques A. Rigid bronchoscopy: Complications in a university hospital. J Bronchol 2003;10:177-81.  Back to cited text no. 4
    
5.
Petrella F, Borri A, Casiraghi M, Cavaliere S, Donghi S, Galetta D, et al. Operative rigid bronchoscopy: Indications, basic techniques and results. Multimed Man Cardiothorac Surg 2014;2014. pii: mmu006.  Back to cited text no. 5
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]



 

Top
  
 
  Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Case Report
   Discussion
   Conclusion
    References
    Article Figures

 Article Access Statistics
    Viewed307    
    Printed2    
    Emailed0    
    PDF Downloaded25    
    Comments [Add]    

Recommend this journal