Home | About us | Editorial Board | Search | Ahead of print | Current Issue | Archives | Instructions | Online submissionContact Us   |  Subscribe   |  Advertise   |  Login  Page layout
Wide layoutNarrow layoutFull screen layout
Lung India Official publication of Indian Chest Society  
  Users Online: 53   Home Print this page  Email this page Small font size Default font size Increase font size


 
  Table of Contents    
LETTER TO EDITOR
Year : 2017  |  Volume : 34  |  Issue : 2  |  Page : 216-217  

Mapleson D continuous positive airway pressure system for weaning of mechanical ventilation in pediatric patients: In response


1 Department of Anesthesiology, Salamanca University Hospital, Salamanca, Spain
2 Medical Scientific Liaison, Boehringer Ingelheim, Germany
3 Department of Anesthesiology, Mostoles University Hospital, Mostoles, Spain
4 Department of Anesthesiology, La Paz University Hospital, Madrid, Spain

Date of Web Publication1-Mar-2017

Correspondence Address:
Miguel Angel Palomero Rodriguez
Department of Anesthesiology, Salamanca University Hospital, Salamanca
Spain
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0970-2113.201310

Rights and Permissions

How to cite this article:
Rodriguez MA, de Arteaga HC, Báez YL, Sánchez Jd, Ferrer AP. Mapleson D continuous positive airway pressure system for weaning of mechanical ventilation in pediatric patients: In response. Lung India 2017;34:216-7

How to cite this URL:
Rodriguez MA, de Arteaga HC, Báez YL, Sánchez Jd, Ferrer AP. Mapleson D continuous positive airway pressure system for weaning of mechanical ventilation in pediatric patients: In response. Lung India [serial online] 2017 [cited 2017 Aug 21];34:216-7. Available from: http://www.lungindia.com/text.asp?2017/34/2/216/201310

Sir,

We are writing in response to the letter from Dr. Mandal et al.[1] regarding our article entitled “Mapleson D continuous positive airway pressure (CPAP) system for weaning of mechanical ventilation (MV) in pediatric patients.” We would also like to thank Dr. Mandal et al. for their kind remarks about our article and offer you the following responses. First of all, regarding first point of their letter, we would like to clarify that all infants and children who received prolonged MV for more than 24 h during a period of 4 years were enrolled in this retrospective observational study.

Extubation failure rates range from 2% to 22%[2],[3] and bear little relationship to duration of MV. We agree that our study showed a higher extubation failure (26%). Patients undergoing major surgery and general anesthesia with muscle relaxation/paralysis have an elevated incidence of intraoperative pulmonary collapse which is associated with worsening intraoperative gas exchange and in some cases, the need for prolonged postoperative respiratory support.[4] We think that our results could be due in part to the characteristics of the study population included in this research, incorporating surgical patients. We would like to clarify that this is a retrospective observational study and the purpose of this research is to show a useful and simple alternative to more complex and expensive CPAP/bilevel positive airway pressure (BiPAP) systems for weaning of MV in children. We agree with Dr. Mandal et al. that it would be interesting to compare the Mapleson D CPAP system with other CPAP/BiPAP devices in a similar situation. Adult studies show that T-piece or pressure support trials for extubation readiness test have been equally effective;[5] hence, we think further high-quality studies compared this device would be necessary.

We have to highlight that this is a retrospective observational study, and the heterogeneity of results might be related with the different clinical characteristics of the patients, different major surgical pathologies enrolled, and with limited and heterogeneous data recorded. We agree that due to the abnormal distribution of the data we should have presented these in median ± interquartile range. Indeed, the results from [Table 3] regarding MV are incorrect and they should be 9/4 instead of 19/22 and 23/4 instead of 13/12. To sum up, we thank the authors about their highlight regarding differences observed comparing mean SpO2, systolic blood pressure, and diastolic blood pressure at baseline continous mandatory ventilation (CMV) and 2 h postextubation. This appreciation is interesting and could be due to different sedation level of the patients enrolled in the study in different phases and related to the discomfort of the patients during CMV phase.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Mandal A, Sahi PK. Mapleson D continuous positive airway pressure system for weaning of mechanical ventilation in pediatric patients. Lung India 2016;34:215-6.  Back to cited text no. 1
    
2.
Edmunds S, Weiss I, Harrison R. Extubation failure in a large pediatric ICU population. Chest 2001;119:897-900.  Back to cited text no. 2
    
3.
Farias JA, Alía I, Retta A, Olazarri F, Fernández A, Esteban A, et al. An evaluation of extubation failure predictors in mechanically ventilated infants and children. Intensive Care Med 2002;28:752-7.  Back to cited text no. 3
    
4.
Brismar B, Hedenstierna G, Lundquist H, Strandberg A, Svensson L, Tokics L. Pulmonary densities during anesthesia with muscular relaxation – A proposal of atelectasis. Anesthesiology 1985;62:422-8.  Back to cited text no. 4
    
5.
Newth CJ, Venkataraman S, Willson DF, Meert KL, Harrison R, Dean JM, et al. Weaning and extubation readiness in pediatric patients. Pediatr Crit Care Med 2009;10:1-11.  Back to cited text no. 5
    




 

Top
  
 
  Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References

 Article Access Statistics
    Viewed288    
    Printed1    
    Emailed0    
    PDF Downloaded26    
    Comments [Add]    

Recommend this journal