Lung India

CASE REPORT
Year
: 2017  |  Volume : 34  |  Issue : 3  |  Page : 273--274

Fibrinolytic administration via EKOS catheter used in pulmonary embolism


Alana James, Satyam Veean, Jayanth H Keshavamurthy, Gyanendra Sharma 
 Department of Radiology, Medical College of Georgia, Augusta University, Augusta, GA 30912, USA

Correspondence Address:
Satyam Veean
Medical College of Georgia, Augusta University, 1120 15th Street, Augusta, GA 30912
USA

Abstract

A 69-year old bed-bound woman presented with chest pain and diaphoresis. Diagnostic imaging led to the diagnosis of bilateral extensive pulmonary emboli extending into all segmental branches. Tissue plasminogen activator (tPA) was administered via 2 separate EKOS catheters. Repeat evaluation after 33 hours revealed improvement of right ventricular size and function. EKOS catheters are useful for administration of fibrinolytics in pulmonary embolism.



How to cite this article:
James A, Veean S, Keshavamurthy JH, Sharma G. Fibrinolytic administration via EKOS catheter used in pulmonary embolism.Lung India 2017;34:273-274


How to cite this URL:
James A, Veean S, Keshavamurthy JH, Sharma G. Fibrinolytic administration via EKOS catheter used in pulmonary embolism. Lung India [serial online] 2017 [cited 2019 Oct 22 ];34:273-274
Available from: http://www.lungindia.com/text.asp?2017/34/3/273/205330


Full Text

 Introduction



This is a case of a 69-year-old woman who presents to the ER with chest pain and diaphoresis. She had been mostly bedbound for the past 2 months due to a stroke 2 months ago with resulting residual hemiplegia. After diagnostic imaging was performed, she was diagnosed with extensive bilateral emboli involving the right and left main pulmonary arteries and extending into all segmental branches. The study decided to use catheter directed tPA via EKOS catheter. tPa was administered via 2 separate catheters over 12 hours for a total of 24mg. Then, the EKOS catheters were removed, and repeat echo done 33 hours after the initial echo showed improvement of right ventricular size and function. This case report aims to show benefits of using EKOS catheters for the administration of fibrinolytics in pulmonary embolism.

 Case Report



A 69-year-old woman presented to the emergency room with chest pain and diaphoresis. She had been mostly bedbound for the past 2 months due to stroke 2 months ago with residual hemiplegia.

Findings

Chest X-ray on admission was normal. Computed tomography (CT) angiogram was performed and showed extensive bilateral emboli involving the right and left main pulmonary arteries and extending into all segmental branches [Figure 1]a and [Figure 1]b and straightening of the interventricular septum [Figure 1]c. Bilateral lower extremity venous duplex ultrasound showed a deep venous thrombus in the left distal popliteal vein [Figure 2]. She was initially treated with heparin. Transthoracic echocardiography (echo) was performed to evaluate for right heart strain and showed severe dilation of the right ventricle and McConnell's sign (right ventricular dysfunction with akinesia of the mid-free wall and hypercontractility of the apex), which is a specific sign of acute pulmonary embolism (PE) [Video 1 [SUPPORTING:1]]. Risks and benefits were discussed with the patient about the use of pulmonary artery catheter-directed tissue plasminogen activator (tPA) in light of her recent stroke 2 months ago. It was decided to use catheter-directed tPA via EKOS catheter. EKOS catheters were placed in the bilateral pulmonary arteries as seen on the chest X-ray [Figure 3]. tPa was administered via two separate catheters over 12 h for a total of 24 mg. Then, the EKOS catheters were removed, and repeat echo done 33 h after the initial echo showed improvement of right ventricular size and function [Video 2 [SUPPORTING:2]].{Figure 1}{Figure 2}{Figure 3}

 Discussion



Although CT angiography remains the first-line imaging study for diagnosing acute PE, echo may be useful in cases of massive PE to evaluate right heart strain to determine the need for thrombolytics. On echo, McConnell's sign can be valuable to demonstrate the cardiac dysfunction caused by an acute PE.[1] In this case, it was particularly important to determine the effects of the clot burden given the patients increased risks associated with tPA administration because of a history of recent stroke. In this case, EKOS catheters were used to administer tPA. The EKOS catheters have ultrasound transducers within the wire of the catheter, which uses ultrasound waves to accelerate the fibrinolytic process, and therefore decrease treatment time and decrease the total dose of thrombolytic agent needed which should translate into decreased morbidity and mortality.[2] A prospective multicenter study on 150 patients with acute massive or submassive pulmonary emboli who underwent ultrasound-facilitated, catheter-directed, low-dose fibrinolysis showed decreased right ventricular dilatation, decreased pulmonary hypertension, reduced clot burden, and decreased intracranial hemorrhages in these patients. Efficacy outcomes were measured within 48 h of initiation of fibrinolytic therapy.[3] In the case presented, there was also improved cardiac function after administration of tPA via EKOS catheters within 48 h. Therefore, this case supports the benefits of using EKOS catheters for the administration of fibrinolytics in PE.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

References

1Patra S, Math RS, Shankarappa RK, Agrawal N. McConnell's sign: An early and specific indicator of acute pulmonary embolism. BMJ Case Rep 2014;2014. pii: Bcr2013200799.
2Owens CA. Ultrasound-enhanced thrombolysis: EKOS EndoWave infusion catheter system. Semin Intervent Radiol 2008;25:37-41.
3Piazza G, Hohlfelder B, Jaff MR, Ouriel K, Engelhardt TC, Sterling KM, et al. A prospective, single-arm, multicenter trial of ultrasound-facilitated, catheter-directed, low-dose fibrinolysis for acute massive and submassive pulmonary embolism: The SEATTLE II Study. JACC Cardiovasc Interv 2015;8:1382-92.